                  艾默生UPS电源英文版说明书
                  发布时间:2016.04.28    浏览次数:8314

                  详情咨询艾默生服务热线:400-619-2138Thank you for purchasing our product. Observe the warnings on the machine and manual strictly and properly keep the manual. Do not operate the UPS before read safety notes and operation instructions.

                  INDEX

                  Chapter 1 Safety Introduction

                  1.1 Description of the Symbols

                  1.2 Safety Notes

                  Chapter 2 Product introduction

                  2.3 UPS appearance

                  2.3.1 Front panel

                  2.3.2 Rear panel

                  2.4 Specification

                  2.4.1 Electric specification

                  2.4.2 Measurement and Weight

                  2.4.3Environmental

                  2.4.4 EMC

                  Chapter 3 Installation

                  3.1 Unfold checking

                  3.2 Wiring cable

                  3.3 Procedure of UPS cable connection

                  3.5 Connected to the computer interface

                  3.6 Installation of intelligence card

                  3.7.3 Operation instruction

                  3.9 Maintenance of the switch

                  3.9.1 Dust-proof networkoptional

                  Chapter 4 Operation

                  4.1 Operation panel

                  4.1.1 ON/OFF button

                  4.1.2 Function button

                   

                   

                   

                   

                  4.1.3 LED operation panel explanation

                  4.1.4 Led panel led indicate

                  4.2 Power

                  4.2.1 Utility power

                  4.2.2 DC without utility power

                  4.3 Shutdown

                  4.4 LED panel light and display

                  4.5 LCD Panel light and display :

                  4.6 LCD panel lcd display content

                  Chapter 5 Maintenance

                  5.1 Maintenance

                  5.2 Battery maintenance

                  6.1 LED Panel trouble shooting

                  6.2 LCD panel trouble shooting

                  Appendix A Rack mounted battery pack

                  Appendix B intelligent slot (Optional)

                  Warranty

                  Chapter 1 Safety Introduction

                  1.1 Description of the Symbols

                  All of the symbols as listed in the table below maybe used in this manual .This symbols are used for reminding users of safety notes for installation, operation ,and maintain.

                  Symbol & Description

                  Symbol

                  Description

                  Caution,danger

                  Danger electric shock

                  Alternating current(AC)

                  Direct current(DC)

                  Protective ground

                  Recycle

                  Do not dispose with ordinary trash

                             1.2 Safety Notes

                  1.Read this manual carefully and thoroughly before operation the UPS and save this manual properly for reference.

                  2. When operating,please pay attention to all the alarming marks and operate in required.

                  3. Avoid direct sunlight, rain, or in a wet environment to use this equipment

                  4.This UPS can not be installed near the  heat source area, or an electric heater, furnace and other similar equipment .

                  5.When placing UPS,leave a distance around to ensure ventilation. When installing,please refer to the instructions

                  6.Wipe with dry goods when cleaning.

                  7. In the event of fire occurring in the vicinity, please use dry powder fire extinguishers. The use of liquid fire extinguishing agents cause electric shock.

                  1.3 Electric safety

                  1. Before power, make sure is properly grounded, and check the wiring and the battery polarity is connected correctly

                  2. When the UPS need to move or re-wiring, disconnect the AC input power and to ensure that UPS is completely shut down, otherwise the output may still be charged, and there is the risk of electric shock

                  3. Please use our attachments and accessories specified.

                  4. To comply with EMC requirements, UPS's output line length should be within 10 meters

                  1.4 Battery safety

                  1. Battery life shorten with arising ambient temperature. Replace battery regularly can ensure it works and to ensure adequate back-up time.

                  2. Battery maintenance only be operated by professional personel who have barrtey knowledge.

                  3. There is risk of electric shock and short circuit the battery current danger. To avoid electric shock injury accident in the replacement battery, please observe the following warning:

                  A. Do not wear watches, rings or similar metal objects

                  B. Use insulated tools

                  C.Wear rubber boots and gloves

                  D. Do not put metal tools or similar metal parts on the battery

                  E. Before the separation of the battery connection terminals,you must first disconnect the load on the battery.

                  4.. Do not expose of batteriy to the fire, they may explode.and endanger safety

                  5. Non-professionals do not open or mutilate the battery, because batteries contains electrolyte acid and other hazardous substances, which will cause skin and eye damage. If you accidentally come into contact with the electrolyte, wash with plenty of water immediately and go to the hospital

                  6. Do not short the positive and negative of the battery electrode, otherwise, it may result in electric shock or fire.

                   1.5 Maintenance

                  1. Method of using the environment and save the life and reliability of this product have an impact,do not work in the following environments:

                  A. Exceed the specfications (temperature 0 ~ 40, relative humidity 20% ~ 90%) of the high and low temperatures and wet places

                  B. Vibration or shocks places

                  C. Metallic dust, corrosive substances, salt and flammable gases

                  2. If the extended period of time is not used, must be UPS (without batteries) stored in a dry environment, the storage temperature range: -25 ~ +55. UPS power, you must warm up the ambient temperature above 0 and keep 2 hours

                   

                  Chapter 2 Product introduction

                  2.1 Product introduction

                  This series of UPS is an advanced on-line uninterruptible power supply sine wave,with bypass maintenance switch and parallel redundant functions. It can provide reliable, high-quality AC power for your precision equipment. It can be widely used from computer equipment ,communication systems to industrial automation equipment. Because of its on-line design, different from the reserve-type UPS, constantly adjusting its input voltage, filter.When the utility power break off, it will have no time to break from the backup battery to provide backup power. In the case of overload or inverter failure, UPS will switch to bypass mode, the utility power supply. If the elimination of overload, UPS will automatically switch back to inverter power supply status.

                    Any of the above models, is divided into Standard and Professional Edition for users to choose.Professional, relative to the Standard Edition, increases EPO switch, manual maintenance bypass switch.

                  2.2 Model type

                  This  series  UPS model  type  show  below.

                           (3)  (x)K [S] [R] [X]

                           (3)  With 3 means three phase input ,or  single phase input

                           (x)  means capacity of ups, 1, 2, 3 for this manual product.  K  means capacity of UPS, KVA

                  [S]     With S means Long backup time type , UPS can connect with external batteries. And without S means ups is standard backup time type.

                  [R]      With R means Rack mounted, without R is Tower mounted.

                           [X]     With X means LCD display panel  and without X means LED display panel.

                   

                  model

                  discription

                  C6K[R][X]

                  6KVA UPS, RACK OR TOWER, LED OR LCD, with inner batteries

                  C6KSR[R][X]

                  6KVA UPS, RACK OR TOWER, LED OR LCD, external   batteries

                  C10K[R][X]

                  10KVA UPS, RACK OR TOWER, LED OR LCD, with inner batteries

                  C10KS[R][X]

                  6KVA UPS, RACK OR TOWER, LED OR LCD, external batteries

                  3C10KS[R][X]

                  10KVA UPS, RACK OR TOWER, LED OR LCD, external batteries

                  3C15KS[R][X]

                  15KVA UPS, RACK OR TOWER, LED OR LCD, external batteries

                  3C20KS[R][X]

                  20KVA UPS, RACK OR TOWER, LED OR LCD, external batteries

                  noteFor C6KRC10KR, battery pack needed, please refer to appendix A

                   

                  2.3 UPS appearance

                  2.3.1 Front panel

                   

                  blob.pngblob.pngblob.pngblob.png

                  1    Computer Interface

                  2    Intelligent slot

                  3    Fan

                  4    Parallel card cover ( optional )

                  5     Input breaker

                  6     Maintain switch cover, ( Maintain switch is optional )

                  7     Wire terminal cover

                  8   Wire fix

                  9   EPO (Optional)

                  2.4 Specification

                  2.4.1 Electric specification

                             model

                  Item

                  C6K

                  C6KS

                  C10K

                  C10KS

                  3C10KS

                  3C15KS

                  3C20KS

                  Power Rating

                  6KVA/4.8KW

                  10KVA/8KW

                  15KVA/12KW

                  20KVA/16KW

                  AC

                  IN

                  Wire method

                  Single phrase or three phase & earth ground

                  Rated Voltage

                  220VAC

                  380VAC

                  Rated Freq

                  50Hz

                  Voltage Range

                  120~275VAC±5

                  Frequency Range

                  45~55±0.5Hz

                  Bypass Range

                  80VAC×(1±5%)285VAC×(1±5%)

                  BAT

                  Rated Bat Voltage

                  192VDCOptional   240V

                  Battery capacity*Quantity

                  12VDC*16Optional 20节)

                   

                  AC

                  OUT

                   

                  Output system

                  Single phrase & earth ground

                  Output voltage

                  220VAC±3%

                  Output frequency

                  46-54HzLine normal

                  50Hz±1%Line abnormal

                  Dynamic voltage transient range

                  <5%

                  Dynamic transient restore

                  < 60ms

                  Waveform

                  Sine Wave THD<3%(linear load) Sine Wave THD<8%(nonlinear   load)

                  Input power factor

                  0.8

                  Overload capability

                  105-125% 30s to bypass

                  Communications

                  RS232(turn to 485), Intelligent slot

                  2.4.2 Measurement and Weight

                  model

                  Size W*H*D(mm)

                  wight (kg)

                  C6KS

                  248×460×500

                  20

                  C10KS

                  248×460×500

                  22

                  C6K

                  248×620×500

                  57

                  C10K

                  248×620×500

                  67.5

                  3C10KS

                  248×620×500

                  27

                  3C15KS

                  248×620×500

                  35

                  3C20KS

                  248×620×500

                  35

                  C6K(S)R

                  438×172×500

                  20

                  C10K(S)R

                  438×172×500

                  22

                  2.4.3 Environmental

                  ITEM

                  Normal range

                  Ambient temperature

                  10℃~ +40℃

                  Environment humidity

                  0~90%,no condensation

                  Altitude

                  Lower than 1000m: no derating

                  Over 1000m :1% derating for every 100m rise

                  Storage temperature

                  -15℃~+45℃

                  2.4.4 EMC

                  ITEM

                  Standard

                  Level

                  ESD

                  IEC61000-4-2

                  LEVEL4

                  RS

                  IEC61000-4-3

                  LEVEL3

                  EFT

                  IEC61000-4-4

                  LEVEL4

                  SURGE

                  IEC61000-4-5

                  LEVEL4

                   